Integrated Density & Background Subtraction

Batch CTCF & Background-Corrected Fluorescence Intensity Analysis

Measure per-cell Integrated Density, local background, and Corrected Total Cell Fluorescence (CTCF) with saturation warnings across multi-condition experiments.

Formats
.czi · .nd2 · .ome.tif · .tif
Price
$199 flat
Delivery
< 24 hours
Quantified overlay for CTCF Fluorescence Intensity Quantification
Raw micrograph for CTCF Fluorescence Intensity Quantification
RawQuantified
Quantification equation
CTCF=IntDencell−(Acell×Iˉbg)\mathrm{CTCF} = \mathrm{IntDen}_{\mathrm{cell}} - \left(A_{\mathrm{cell}} \times \bar{I}_{\mathrm{bg}}\right)

Calculated directly on raw 12-bit/16-bit pixel arrays with automated saturation (>1% clipped pixels) and exposure-mismatch warnings.

Typical lab studies

  • Immunofluorescence protein expression comparison across knockout vs. wild-type cells
  • Nuclear-to-cytoplasmic translocation ratios (e.g., NF-kB, YAP/TAZ, p-STAT3)
  • Reporter fluorescence quantification across multi-dose treatment series
Delivered in your ZIP
  1. 1Per-cell Integrated Density, area, local background median, and CTCF tables (Excel & CSV)
  2. 2Automatic acquisition metadata audit flagging exposure or bit-depth mismatches
  3. 3300 dpi SVG/PDF intensity distribution figures (violin/box + replicate means)
  4. 4Segmentation confirmation overlays + one-click outlier removal workspace
  5. 5Reproducible Python script and Methods paragraph

Manual ImageJ vs. MicroQuant batch

DimensionManual ImageJ / CROMicroQuant ($199 batch)
Background ROI samplingManual 3-box drawing per imageAutomated cell-free local background estimation
16-bit saturation checkOften overlooked until reviewer asksAutomatic per-image saturation percentage report
Statistical aggregationManual copy-paste from ImageJ Results to PrismDirect Excel + tested p-values + SVG figures

Frequently asked questions

Does MicroQuant modify or auto-scale my 16-bit fluorescence pixel values?

Never. Integrated Density, background median, and CTCF are computed strictly on unmodified raw pixel arrays. Display contrast stretching is applied only to separate PNG preview overlays.

What happens if one treatment group had a different camera exposure time?

Our ingestion QC checks acquisition metadata across all uploaded vendor files and flags any exposure-time, bit-depth, or pixel-saturation (>1% clipped pixels) mismatch inside the delivery report.

Can I also quantify nuclear-to-cytoplasmic translocation or dual-channel colocalization?

Yes. Standard Batch supports nuclear + marker intensity quantification, and Large Study ($499) includes multi-channel colocalization (Pearson's r & Manders' M1/M2) and ring-expanded cytoplasmic ratios.