Clonogenic Colony Counting in ImageJ: Tuning Analyze Particles Size & Circularity
Clonogenic survival assays require counting every colony exceeding 50 cells across dozens of crystal violet–stained 6-well plates. Counting by eye with a marker pen causes fatigue drift across doses, while naive ImageJ thresholding picks up bright plastic well-wall reflections as false colonies.
Plating Efficiency (PE) and Surviving Fraction (SF) formulas
Normalize treated wells against the untreated control Plating Efficiency so cell-line seeding differences cancel out across replicates:
Standard Franken et al. (Nature Protocols) clonogenic survival equations. Report both colony count and total stained area fraction when colonies begin merging at low doses.
Step-by-step ImageJ colony counting procedure (6-well plates & dishes)
Photograph or flatbed-scan every plate under uniform diffused backlighting with identical focus height, then lock one well-diameter ROI across all wells:
- Convert to grayscale
Open the plate scan and run (or split RGB channels and keep the Green channel, where purple crystal violet has peak absorption).
- Mask out plastic well rim
Draw an Oval ROI inset 3–5% inside the inner well edge, add it to
ROI Manager, and run on a duplicate of each well so rim glare is completely excluded. - Flatten lighting gradient
Run (check Light background for dark crystal violet colonies on a white flatbed scan;
Rolling Ballradius 100–200 px). Threshold & split merged colonies: Run (
TriangleorYenworks well on sparse dark colonies), convert via , then apply .- Tune Analyze Particles
Open , set Size to match your 50-cell minimum colony area (e.g., 50–Infinity px² at 300 dpi scan, or calibrated mm²), set
Circularityto 0.35–1.00, check Exclude on edges and Show Outlines.
Tuning Size & Circularity parameters for clean colony counts
Validate your minimum particle area against 3 manually verified reference colonies from a control well before running the full experiment:
| Parameter / issue | Recommended setting | What goes wrong if mis-tuned |
|---|---|---|
| Minimum Size cutoff | Match measured area of a verified ~50-cell colony (typically 0.15–0.35 mm²) | Too small counts single stained dust specks; too large drops slow-growing treated colonies. |
Circularity (4π × Area / Perimeter²) | 0.35–1.00 for round colonies; lower to 0.20 if irregular or merged pairs occur | Setting 0.70–1.00 excludes legitimate twin colonies that touch along one edge. |
| High-density confluent wells | Report both colony count and % Area covered inside the circular well ROI | Heavy colony merging collapses raw object count even when cell survival is high. |